tech_documents:voip:patton_smartnode_3cx

If still on the Smartnode firmware revision, use the Patton ISDN T1 instead of the Trinity specific model.

  • The smartnode needs to be on the same subnet as the 3CX server
  • On a SN4970 factory reset is done by holding reset button for 5 seconds only, any longer will not reset the device.
  • The smartnode detector didn't work for me, I had to check DHCP logs to find the IP of the smartnode after factory reset
  • Web logging into webUI, create new admin account and password then write/save config, otherwise it will not be saved after a reboot
  • Add the Patton device in 3CX, then download the device config and upload it to the Patton device and commit/save/reboot.
  • When connecting to an Adtran or similar, a crossover cable is needed between the Adtran and Patton device.
  • The 3CX generated config worked for a Comcast PRI without modification.
  • tech_documents/voip/patton_smartnode_3cx.txt
  • Last modified: 2022/01/12 06:10
  • by jacob.hydeman